Surveillance WebCam Product Documentation   Home Page    Table of Contents

Remote Commands

Location: Remote User Interface

Remote commands are issued through your web browser. They perform the same function as menu items. The Admin Page, has all the remote commands. Other web pages User Page, Mobile User Page, Mobile Admin Page, have a subset of the commands found on the Admin Page.

Below is a copy of the Admin Page with all the remote commands. Click on the links to find an explanation of the function. Additional notes are provide in italics right below the command.

All remote command web pages have default values beside the commands. These default values are not the actual value of the parameter in the Video Surveillance WebCam Software itself. Use command Get Program Status, to see the actual values of parameters in the Video Surveillance WebCam Software. Get Program Status is also a good way to check if the command you executed below actually registered in the program.

 

Admin Page


Shortcuts Down this page

Arm Alarms Startup
Logon Save FTP
Status Motion Detection Load Config
Review Video Switching Close Files
Remote View Video Audio
File Streaming Files Bottom


Re-Log On to Program if Log On Timed Out

Enter Password

Is the password set in the Video Surveillance WebCam Software. Recommend use and enable remote password if using Web Server. If program automatically logs you off you can re-logon here.

Log Off

Always log off when finished remote access. 


Program Status

Get Program Status

Get Number of Frames Save
Shows the total number of video frames saved. Quick way to check if any motion detection happened. Use Clear Program Status to set this value back to 0.

Show Alarm History Log
Shows the all of the Alarm History Log. Related to Alarm History dialog.

Show Monitoring Program Log

Show Web Server Log

Show FTP Video File Log

Clear Program Status (Frames Saved to 0)


Review Video Files

Review Video Files
Returns a web page with all the saved video capture files. Click on file name link and file should start to play in Windows Media Player. If not download file, right mouse click file, select - Save Target As .., File Name = *.avi (not *.htm). After downloaded, play/review avi file on your computer with Media Player by clicking on the file with your mouse.


Close Video Files


Run - Remote View

Streams live video and audio from your cameras to you at a remote computer through Windows Media Player. 

Stream live video , with config file:

Starts streaming live video. Same function as menu item Stream. The Streaming Configuration File selected must already exist, and be configured right. After enter, select link in the Media Player Page to display the video in Windows Media Player. If link does not work use Manual Method for Remote Viewing.

Monitor
After streaming live video, don't forget to switch the program back to Monitor Mode or Record Mode.

Record

Stop
Stops the Video Surveillance WebCam Software. You may have to do this in order to change some settings.

Switch to Camera Number  

When doing live video stream it will switch to the camera you want and stay there while viewing with Windows Media Player.  

Enable Auto Camera Switching

If you Switch Camera, after you can start auto cycling through the cameras again. You may have to Stop and Stream again for this setting to take effect.

Set Auto Camera Switching Time Period (1-86K sec)

Enable Live Streaming Timeout

Set Live Streaming Timeout time(1-70K min.)

Set After Live Streaming State

Get Live Streaming Video Port
Useful if doing Manual Method of Remote Viewing


File Streaming - Remote View

Streams video of your video captured files to you at a remote computer through Windows Media Player.

Get Stream File Program Status
Tells you if File Streaming is running.

Connect with Media Player
Gives you the Media Player Page where you can click on a link to view the streamed files through Windows Media Player. If link does not work use Manual Method for Remote View.

Select a File To Stream
Presents a list of files to stream. Click on one of the files and it will be streamed. Streams the file and stops newly created files from being loaded and streamed.

Select a File Stream Forward From
To stream a group of files. It streams  x number of files forward from the one you select. X number is setting specified in the Stream File Program, and can also be set with Number of files to play forward, below. Streams the selected files and stops newly created files from being loaded and streamed.

Stream New Files
Sets the Stream File Program to stream all newly created files either by Monitor Mode or Record Mode. Starts accepting newly created files, loads, and streams them.

Stop File Streaming
Causes the Stream File Program to stop streaming video to the end user, it does not shutdown and close the program. Newly created files are loaded by not streamed.

Run File Streaming program

Launches the Stream File Program to run. Or shuts down the Stream File Program from running.

Just Stream Files with Alarms

Only streams files with email or sound alarms in them, and does not stream other files also recorded. Effective in Monitor Mode only.

Allow some commands without logon

Allows executing some file streaming commands from an email with an alarm it, without having to logon to the Video Surveillance WebCam Software.

Change profile:

Streaming of files is configured with Windows Media Encoder Profiles. You select the profile number you would like to stream files with. The profile has to exist already or be one already created the user.

Number of files to play forward (1-25)

Sets the number of files to stream forward from, when you execute the Select a File Stream Forward From, command above.

Get Stream File Video Port
Returns video streaming port which Stream File is streaming through so you cannot to it with Windows Media Player when using the Manual Method for Remote View.


Alarms

ARM (Activate Alarms)
DISARM (Deactivate Alarms)

Arms or disarms the alarms. Good for arming or disarming your system from a mobile device when entering or leaving your home.

For camera number Frames for alarm are
and use Detection Email Sound NoMotion Detection

For a particular camera enable or disable alarms, and set the frames for an alarm.

Alarm Polling Time Interval(1-1M sec)

How frequently should the Video Surveillance WebCam Software check for alarm conditions in terms of seconds.

Set Time Between Email Alarms(1-1M sec)

If there is an alarm how many seconds between email notifications would you like. Prevents you from being swamped by emails coming to frequently.

 



Save Program Configuration

 

Save Configuration as File

After you change settings in the program with this Admin Page, and you want to keep the settings, do a Save Configuration. Use 0 to save to the Video Surveillance WebCam Software's main startup configuration file, and 1-10 for configurations files to be loaded by timer.


Restart the Program

Do not use unless necessary. Restarts the program. For settings that require a program restart, or if the program needs restarting.

 


Program Settings

 

Motion Detection

For Camera Sensitivity(0-100) Filter(0-1000)

Sets the motion detection sensitivity and noise filter value for a particular camera. First select the camera then set the values and then click enter.

Detection Region for Camera x1 y1 x2 y2

Sets the motion detection rectangular region for a particular camera. Use Get Program Status, to see what size your current images are so you know the max value of x and y ie the size of the image eg 320x240. x1,y1 are the top left points of the rectangle in the image, and x2,y2 are the bottom right points of the rectangle in the image.

 


Camera Switching

Select Camera Enable Camera Min Frames Max Frames

To enable or disable a camera. And the minimum and maximum amount of frames to display for a camera when the Video Surveillance WebCam Software is monitoring. Must be stopped to change.

Switch Faster(0) Slower(30)

How many frames to drop when switching between cameras in case there is switching noise in the camera video image.

Default Camera

When the program stops which camera number to display in the main video window of the program.

 


Video

Use Separate Camera Brightness

Enable Video Surveillance WebCam Software to adjust the brightness for each camera while it runs.

For Camera Brightness(0-255) Contrast(0-255)

If Use Separate Camera Brightness is enabled changes brightness of an individual camera. If Use Separate Camera Brightness is disabled changes the brightness of all cameras to the same value.

Set Video Compressor (0-30)

Should not or rarely used to change the which video compressor the Video Surveillance WebCam Software uses One must know the compressor index number.

 


Video File Recording

Record More (0-1800)

Set Frames Per File (2-323K)

Set Number of  Files (12-1M)

Playback speed (1-100)

Record to separate files

Set Min Disk Space(4MB-2000MB)

 


Audio Recording

Enables recording of audio to file - must be in Stopped Mode to enable.

Record Audio

Record Time Trigger on Any Motion Trigger from Camera

Amount of time to record in Monitor Mode if motion on any camera. If Trigger checked then recording triggered from the camera number entered. Works only if  Use Sound Detection below is turned off, and after enable Record Audio above.

 

Use Sound Detection

Enables sound detection recording, also enables or disables Record Audio above at the same time.

Sound Level Average Above

Sets the sound level to trigger sound detection and recording audio.

 


Startup

Startup Mode

Startup Armed

Enable IP Address Tracking

Show Errors

 


FTP Video Files 

Enable FTP of Video Files

Set Maximum Number of Files to FTP (1-1M)




Configuration by Timer

Program configuration files must already exist in order to load them.

Load Now Program Configuration File Number

Enable Configuration by Timer

Time Slot Sun Mon Tue Wed Thur Fri Sat Time(0-23) File(0-10)

Set the time and day when a program configuration file is to be loaded. One can set 4 time slots. Use Get Program Status to check and verify new settings.

 


 

Top